Applications
Because
of its multiplexing capability, the TC3007 is often used to increase
existing fiber optic cable capacity in LAN or Telephony environments
that require connecting different fiber types or wavelengths,
regenerating optical signals and/or extending transmission distances.
Typical environments include PABX, Ethernet, Fast Ethernet, Token
Ring, FDDI, ATM and SONET (OC1 & OC3).

Top
Description
The
TC3007 Multimode-to-Single Mode Fiber Optic Converter converts multimode
formats to single mode formats, or vice versa, for data transmission up to
200 Mbps. Transmission
distances to more than 50 km are possible with the Laser 1550nm option
(34dB loss budget).
The
TC3007 functions both as a Fiber Optic Mode Converter/Repeater and a
2-Channel Wave Division Multiplexer.
This benefits users by effectively doubling existing fiber cable
capacity in addition to its mode conversion/repeater functions.
The
TC3007 will convert or repeat all popular wavelengths including 850nm,
1300nm or 1550nm. It is compatible with most communication technologies
including Ethernet, Fast Ethernet, Token Ring, TAXI, OC1/OC3, ATM, FDDI
and SONET. It is completely
transparent to incoming data and protocols.
The
TC3007 provides users with several key features including Local/Remote
Loopback, Test Signal Generator, Dry Contact Alarm, Audible Alarm Buzzer,
Power Redundancy, and Standalone or Rack Mount
modularity.
The
Test Signal Generator and Dry Contact Alarm are particularly beneficial.
The Signal Generator (160Mbps) helps technicians conduct various
installation tests including fiber link verifications.
The Dry Contact Alarm, which includes an audible alarm buzzer,
identifies Optical Signal Loss on either the multimode or single mode
ends.
Power
redundancy is load sharing and switches over automatically in the event of
a failure.
Power can be either 12VDC, 24VDC, -48VDC, 115/230VAC.
Standalone versions are modular, i.e. used either in a standalone
case or in a rack mount assembly.
Standard connectors are ST or FC type.
An extreme temperature version (-20° to 70°C), Model TC3007T, is
also available.
A
terminal block connector on the rear panel provides for the dry contact
relay alarm.
Normally in the OPEN position, any loss of electrical or optical
signal will trigger an alarm condition and force the switch to the CLOSED
position.
This relay can be used in conjunction with an external device to
monitor the condition of the link.
Top
Technical
Specifications
| Data
Rates |
| Up
to 200 Mbps |
| Optical
- Single Fiber Side |
| Transmitter |
LASER,
HI-POWER LASER |
| Receiver |
PIN
Diode |
| Wavelength |
1300nm, 1550nm Single Mode |
| Fiber
Optic Connectors |
ST
or FC |
| Loss
Budget (1300/1550nm) |
Single
Mode LASER: 25dB
Single Mode Hi-Power LASER: 32dB |
| Optical
- Dual Fiber Side |
| Transmitter |
LED/ELED |
| Receiver |
PIN
Diode |
| Wavelength |
850/1300nm
Multimode
1300nm Single Mode |
| Fiber
Optic Connectors |
ST
or FC |
| Loss
Budget (850/1300nm) |
Multimode
LED: 16dB
Single Mode ELED: 16dB |
| System
|
| Bit
Error Rate |
1
in 1010
or better |
|
| Visual
Indicators |
| System |
PWR A, PWR B,
VccA, VccB |
| Optical
Signal Status |
MM
RX, MM TX, SM RX, SM TX |
| Alarm |
| Dry
Contact |
Normal
Open |
| Power |
| Standard |
12VDC @
700mA (max) |
| Optional |
24VDC,
-48VDC, or 115/230VAC (with external power cube) |
|
Temperature
|
| Operating |
-10° to
50°C |
| Hi-Temp
(optional) |
-20° to 70°C |
| Storage |
-40° to 90°C |
| Humidity |
95% non-condensing |
| Physical
(Standalone/Wallmount Unit) |
| Height |
(3.53
cm) 1.4" |
| Width |
(18.14
cm) 7.1" |
| Depth |
(16.57
cm) 6.5" |
| Weight |